ARTICLE · 1001494
wps/Scheduler出现错误SCHD0076E
本文适用于
HCL Portal Server 8.5 and later version
问题
Portal启动后,wps/Scheduler立即出现SCHD0076E错误,如下所示:
==================================================
[Date Timestamp] 000000ec LeaseAlarm I CWSCH0133I: Scheduler WPSTaskScheduler (wps/Scheduler) has acquired the lease and will run all tasks on this application server.
...
[Date Timestamp] 000001fc AlarmListener E CWSCH0076E: Scheduler resource WPSTaskScheduler (wps/Scheduler) was unable to fire a notification event of FIRING for task with task id 36201 because the following error occurred: CWSCH0137E: Unable to create EJB instance for NotificationSink: java.rmi.RemoteException: CORBA TRANSIENT 0x4942fe07 No; nested exception is:
org.omg.CORBA.TRANSIENT: initial and forwarded IOR inaccessible vmcid: IBM minor code: E07 completed: No
==================================================
原因
Scheduler中的某些数据可能已损坏,从而导致上面显示的错误。
解决方法
1) 运行如下任务:
ConfigEngine.sh|bat action-clean-scheduled-tasks.
2) 重启Portal。